KEY TAKEAWAY
A container packages a treatment process; it does not remove the need for site engineering and commissioning.
Set the process requirements first
Start with a representative feed analysis, required treated-water specification and demand profile. Identify whether the source is municipal, borehole, brackish or seawater. The process design determines the equipment that must fit within the enclosure.
Agree operating hours, storage and redundancy requirements before choosing the container size. Confirm the treatment boundaries, including pretreatment, post-treatment and any external tanks or pumps.
Review the working environment
The enclosure should provide adequate operating and service access. Ask how heat, ventilation, humidity, lighting, electrical distribution and corrosion exposure will be addressed for the destination site.
Component removal paths matter as much as day-to-day access. Review how membranes, pumps and vessels can be serviced, and identify what must remain outside the container.
Coordinate transport and site readiness
Ask for the packed dimensions, mass, lifting arrangement and delivery scope. Confirm the local foundation, unloading access and connection points before shipment. Shipping and import requirements depend on the destination and agreed terms.
- Feed analysis, demand and product-water targets
- Site climate and available electrical supply
- Container layout and service access
- External pipework, tanks and drainage
- Transport, unloading and local installation responsibilities
Define the acceptance and support plan
Agree the commissioning procedure, performance checks and documents to be supplied. Specify operator training, recommended spares and any remote support arrangements. A factory check and a site acceptance check should have clearly defined scopes.